samsinn PWR simulator — tag binding¶
Maps each canonical procedure tag to a samsinn-internal simulator variable path. Built from the canonical tag catalogue. 113 of 113 tags bound.
Bindings¶
| Tag | sim-path | Units | Equipment | Description |
|---|---|---|---|---|
| «ACCUM-1» | ess.accumulator.1.discharge_valve |
enum[OPEN,CLOSED] | si-system | accumulator tank 1 (cold-leg loop 1) discharge isolation |
| «ACCUM-2» | ess.accumulator.2.discharge_valve |
enum[OPEN,CLOSED] | si-system | accumulator tank 2 (cold-leg loop 2) discharge isolation |
| «ACCUM-3» | ess.accumulator.3.discharge_valve |
enum[OPEN,CLOSED] | si-system | accumulator tank 3 (cold-leg loop 3) discharge isolation |
| «ACCUM-4» | ess.accumulator.4.discharge_valve |
enum[OPEN,CLOSED] | si-system | accumulator tank 4 (cold-leg loop 4) discharge isolation |
| «AEJ-RAD» | rad.condenser.air_ejector |
cps | condenser | condenser air-ejector radiation monitor |
| «AFW-A-CV» | afw.a.cv_position |
percent | afw-system | SG-A AFW control valve position |
| «AFW-B-CV» | afw.b.cv_position |
percent | afw-system | SG-B AFW control valve position |
| «AFW-C-CV» | afw.c.cv_position |
percent | afw-system | SG-C AFW control valve position |
| «AFW-D-CV» | afw.d.cv_position |
percent | afw-system | SG-D AFW control valve position |
| «AFW-FLOW» | afw.header.flow |
gpm | afw-system | aggregate AFW flow (header total) |
| «AFW-PUMP-A» | afw.pump.a.status |
enum[STOPPED,RUNNING,FAULT] | afw-system | motor-driven AFW pump A status |
| «AFW-PUMP-B» | afw.pump.b.status |
enum[STOPPED,RUNNING,FAULT] | afw-system | motor-driven AFW pump B status |
| «AFW-PUMP-T» | afw.pump.tdafw.status |
enum[STOPPED,RUNNING,FAULT] | afw-system | turbine-driven AFW pump status |
| «ARV-A» | secondary.arv.a.position |
enum[OPEN,CLOSED,INTERMEDIATE] | sg-a-msl | SG-A atmospheric relief valve position |
| «ARV-B» | secondary.arv.b.position |
enum[OPEN,CLOSED,INTERMEDIATE] | sg-b-msl | SG-B atmospheric relief valve position |
| «ARV-C» | secondary.arv.c.position |
enum[OPEN,CLOSED,INTERMEDIATE] | sg-c-msl | SG-C atmospheric relief valve position |
| «ARV-D» | secondary.arv.d.position |
enum[OPEN,CLOSED,INTERMEDIATE] | sg-d-msl | SG-D atmospheric relief valve position |
| «BACKFILL-VALVE» | secondary.backfill.valve |
enum[ISOLATED,AFW,CONDENSATE,FAULT] | afw-system | ruptured-SG backfill alignment valve (condensate or AFW source selector) |
| «BAT-LVL» | cvcs.bat.level |
percent | charging-system | boric acid tank level |
| «BLOCK-456A» | rcs.pressurizer.block.456a.position |
enum[OPEN,CLOSED] | pressurizer | pressurizer PORV 456A block valve position |
| «BLOCK-456B» | rcs.pressurizer.block.456b.position |
enum[OPEN,CLOSED] | pressurizer | pressurizer PORV 456B block valve position |
| «BLOWDOWN-A» | secondary.blowdown.a.position |
enum[OPEN,CLOSED] | sg-a | SG-A blowdown isolation valve position |
| «BORATE-FLOW» | cvcs.borate.flow |
gpm | charging-system | emergency boration flow rate |
| «BUS-A-EMERG» | electrical.bus.emerg_a.energized |
bool | bus-a-emerg | emergency 4kV bus A energization status |
| «BUS-B-EMERG» | electrical.bus.emerg_b.energized |
bool | bus-b-emerg | emergency 4kV bus B energization status |
| «CCW-RAD» | rad.ccw.let_hx_outlet |
rem_per_hr | rad-monitoring | component cooling water outlet radiation monitor (letdown HX outlet) |
| «CET-AVG» | rcs.core_exit.thermocouple.avg |
degF | rcs | core-exit thermocouple average (5+ representative locations across the core) |
| «CHG-FLOW» | cvcs.charging.flow |
gpm | charging-system | charging flow rate |
| «CHG-PUMP-A» | cvcs.charging_pump.a.status |
enum[STOPPED,RUNNING,FAULT] | charging-system | charging pump A status |
| «CHG-PUMP-B» | cvcs.charging_pump.b.status |
enum[STOPPED,RUNNING,FAULT] | charging-system | charging pump B status |
| «CONDENSER-VAC» | secondary.condenser.vacuum |
inhga | secondary | condenser vacuum (absolute pressure) |
| «CSPRAY-A» | ess.cspray_pump.a.status |
enum[STOPPED,RUNNING,FAULT] | containment-spray | containment spray pump A status |
| «CSPRAY-B» | ess.cspray_pump.b.status |
enum[STOPPED,RUNNING,FAULT] | containment-spray | containment spray pump B status |
| «CST-LVL» | secondary.cst.level |
percent | afw-system | condensate storage tank level |
| «CTMT-NG» | rad.containment.noble_gas |
uCi_per_cc | containment | containment noble-gas activity monitor |
| «CTMT-PR» | containment.pressure |
psig | containment | containment building pressure |
| «CTMT-RAD» | rad.containment.high_range |
rem_per_hr | containment | containment area radiation monitor |
| «CTMT-SUMP-LVL» | containment.sump.level |
percent | containment | containment recirculation sump level |
| «CTMT-TEMP» | containment.temperature.avg |
degF | containment | containment average temperature |
| «DC-BUS-LVL» | electrical.dc_bus.voltage |
volts_dc | dc-bus | vital DC bus voltage (representative) |
| «DG-A» | electrical.dg.a.status |
enum[STOPPED,STARTING,RUNNING,LOADED,FAULT] | emergency-dg-a | emergency diesel generator A status |
| «DG-B» | electrical.dg.b.status |
enum[STOPPED,STARTING,RUNNING,LOADED,FAULT] | emergency-dg-b | emergency diesel generator B status |
| «HL-FLOW» | ess.hl_inject.header_flow |
gpm | si-system | hot-leg injection header flow |
| «HL-INJECT-A» | ess.hl_inject.a.alignment |
enum[ISOLATED,ALIGNED,FAULT] | si-system | hot-leg injection train A alignment |
| «HL-INJECT-B» | ess.hl_inject.b.alignment |
enum[ISOLATED,ALIGNED,FAULT] | si-system | hot-leg injection train B alignment |
| «HV-LINE» | rcs.head_vent.line |
enum[ISOLATED,VENTING,FAULT] | rcs | reactor vessel head vent line position / activity |
| «LET-FLOW» | cvcs.letdown.flow |
gpm | charging-system | letdown flow rate |
| «LET-ISOL» | cvcs.letdown.isolation |
enum[OPEN,CLOSED] | charging-system | CVCS letdown isolation valve |
| «LO-HEAD-FLOW» | ess.lo_head.header_flow |
gpm | si-system | low-head SI / RHR header flow |
| «MAB-RAD» | rad.mab.area |
rem_per_hr | rad-monitoring | main auxiliary building area radiation monitor |
| «MFW-A-CV» | secondary.mfw.a.cv_position |
percent | mfw-system | SG-A main feedwater control valve position |
| «MS-HEADER-PR» | secondary.ms_header.pressure |
psig | secondary | main steam header pressure |
| «MSIV-A» | secondary.msiv.a.position |
enum[OPEN,CLOSED,INTERMEDIATE] | sg-a-msl | SG-A main steam isolation valve position |
| «MSIV-B» | secondary.msiv.b.position |
enum[OPEN,CLOSED,INTERMEDIATE] | sg-b-msl | SG-B main steam isolation valve position |
| «MSIV-C» | secondary.msiv.c.position |
enum[OPEN,CLOSED,INTERMEDIATE] | sg-c-msl | SG-C main steam isolation valve position |
| «MSIV-D» | secondary.msiv.d.position |
enum[OPEN,CLOSED,INTERMEDIATE] | sg-d-msl | SG-D main steam isolation valve position |
| «N2-SUPPLY» | secondary.arv.n2_supply.pressure |
psig | arv-system | ARV nitrogen-supply pressure |
| «NAOH-LVL» | ess.cspray.additive_tank.level |
percent | containment-spray | containment-spray sodium hydroxide additive tank level |
| «NIS-IR» | nis.intermediate_range.avg |
amps | nuclear-instrumentation | nuclear instrumentation intermediate range |
| «NIS-PR-AVG» | nis.power_range.avg |
percent | nuclear-instrumentation | nuclear instrumentation power-range average (4-channel) |
| «NIS-SR» | nis.source_range.count_rate |
cps | nuclear-instrumentation | nuclear instrumentation source range count rate |
| «PHASE-B-SIG» | ess.phase_b.actuation_signal |
bool | containment | containment Phase B isolation signal (latched) |
| «PORV-456A» | rcs.pressurizer.porv.456a.position |
enum[OPEN,CLOSED,INTERMEDIATE] | pressurizer | pressurizer PORV 456A position |
| «PORV-456B» | rcs.pressurizer.porv.456b.position |
enum[OPEN,CLOSED,INTERMEDIATE] | pressurizer | pressurizer PORV 456B position |
| «PRIMARY-WATER-VALVE» | cvcs.primary_water.makeup_valve |
enum[OPEN,CLOSED] | charging-system | primary water makeup isolation valve |
| «PT-455» | rcs.pressurizer.pressure_wr |
psig | pressurizer | pressurizer pressure (wide range) |
| «PZR-HTR» | rcs.pressurizer.heaters.status |
enum[OFF,ON,FAULT] | pressurizer | pressurizer heater bank energization status |
| «PZR-LVL» | rcs.pressurizer.level |
percent | pressurizer | pressurizer level |
| «RCP-1» | rcs.rcp.1.status |
enum[STOPPED,RUNNING,FAULT] | rcp-1 | reactor coolant pump 1 status |
| «RCP-2» | rcs.rcp.2.status |
enum[STOPPED,RUNNING,FAULT] | rcp-2 | reactor coolant pump 2 status |
| «RCP-3» | rcs.rcp.3.status |
enum[STOPPED,RUNNING,FAULT] | rcp-3 | reactor coolant pump 3 status |
| «RCP-4» | rcs.rcp.4.status |
enum[STOPPED,RUNNING,FAULT] | rcp-4 | reactor coolant pump 4 status |
| «RCS-BORON» | rcs.boron.concentration |
ppm | rcs | RCS boron concentration (sampled) |
| «RHR-HX» | ess.rhr.hx_outlet_temp |
degF | rhr-system | RHR heat-exchanger outlet temperature (representative) |
| «RHR-ISOL» | ess.rhr.isolation_valve |
enum[OPEN,CLOSED] | rhr-system | RHR system isolation valve (representative) |
| «RHR-PUMP-A» | ess.rhr_pump.a.status |
enum[STOPPED,RUNNING,FAULT] | rhr-system | residual heat removal pump A status |
| «RHR-PUMP-B» | ess.rhr_pump.b.status |
enum[STOPPED,RUNNING,FAULT] | rhr-system | residual heat removal pump B status |
| «ROD-POS-AVG» | rcs.rod.position.avg |
steps_withdrawn | rod-control-system | average control rod bottom position |
| «RT-PB» | rps.manual_trip.pushbutton |
enum[NORMAL,DEPRESSED] | reactor-protection-system | reactor trip pushbutton (front-panel) state |
| «RVLS-DYN» | rcs.rvls.dynamic.level |
percent_collapsed_liquid | rcs | reactor vessel level indication system, dynamic-pressure-compensated channel |
| «RWST-LVL» | rwst.level |
percent | rwst | refueling water storage tank level |
| «SG-A-LVL-NR» | secondary.sg.a.level_nr |
percent | sg-a | SG-A narrow-range level |
| «SG-A-N16» | rad.msl.a.n16 |
cps | sg-a-msl | SG-A main steam line N-16 radiation monitor |
| «SG-A-PR» | secondary.sg.a.steam_pressure |
psig | sg-a | SG-A steam pressure |
| «SG-B-LVL-NR» | secondary.sg.b.level_nr |
percent | sg-b | SG-B narrow-range level |
| «SG-B-N16» | rad.msl.b.n16 |
cps | sg-b-msl | SG-B main steam line N-16 radiation monitor |
| «SG-B-PR» | secondary.sg.b.steam_pressure |
psig | sg-b | SG-B steam pressure |
| «SG-C-LVL-NR» | secondary.sg.c.level_nr |
percent | sg-c | SG-C narrow-range level |
| «SG-C-N16» | rad.msl.c.n16 |
cps | sg-c-msl | SG-C main steam line N-16 radiation monitor |
| «SG-C-PR» | secondary.sg.c.steam_pressure |
psig | sg-c | SG-C steam pressure |
| «SG-D-LVL-NR» | secondary.sg.d.level_nr |
percent | sg-d | SG-D narrow-range level |
| «SG-D-N16» | rad.msl.d.n16 |
cps | sg-d-msl | SG-D main steam line N-16 radiation monitor |
| «SG-D-PR» | secondary.sg.d.steam_pressure |
psig | sg-d | SG-D steam pressure |
| «SI-FLOW» | ess.si.header_flow |
gpm | si-system | high-head SI header flow |
| «SI-PUMP-A» | ess.si_pump.a.status |
enum[STOPPED,RUNNING,FAULT] | si-system | high-head SI pump A status |
| «SI-PUMP-B» | ess.si_pump.b.status |
enum[STOPPED,RUNNING,FAULT] | si-system | high-head SI pump B status |
| «SI-SIG» | ess.si.actuation_signal |
bool | si-system | safety injection actuation signal (latched) |
| «SPRAY-FLOW» | ess.cspray.header_flow |
gpm | containment-spray | containment spray total flow (header) |
| «STEAM-DUMP» | secondary.steam_dump.available |
bool | secondary | condenser steam dump availability (auto-permissive flag) |
| «SUB-MARGIN» | rcs.subcooling_margin |
degF | rcs | RCS subcooling margin (T_sat at PT-455 minus hot-leg temperature) |
| «SUMP-SCREEN-DP» | ess.sump.strainer.dp |
psid | si-system | containment sump strainer differential pressure |
| «TAVG» | rcs.t_avg |
degF | rcs | RCS average temperature (4-loop average) |
| «TDAFW-SPEED» | afw.tdafw.turbine_speed |
rpm | afw-system | turbine-driven AFW pump turbine speed |
| «TE-411-COLD» | rcs.loop1.t_cold |
degF | rcs-loop-1 | RCS loop 1 cold-leg temperature |
| «TE-411-HOT» | rcs.loop1.t_hot |
degF | rcs-loop-1 | RCS loop 1 hot-leg temperature |
| «TE-421-COLD» | rcs.loop2.t_cold |
degF | rcs-loop-2 | RCS loop 2 cold-leg temperature |
| «TE-421-HOT» | rcs.loop2.t_hot |
degF | rcs-loop-2 | RCS loop 2 hot-leg temperature |
| «TE-431-COLD» | rcs.loop3.t_cold |
degF | rcs-loop-3 | RCS loop 3 cold-leg temperature |
| «TE-431-HOT» | rcs.loop3.t_hot |
degF | rcs-loop-3 | RCS loop 3 hot-leg temperature |
| «TE-441-COLD» | rcs.loop4.t_cold |
degF | rcs-loop-4 | RCS loop 4 cold-leg temperature |
| «TE-441-HOT» | rcs.loop4.t_hot |
degF | rcs-loop-4 | RCS loop 4 hot-leg temperature |
| «TRIP-BKR-A» | rps.trip_breaker.a.position |
enum[OPEN,CLOSED] | reactor-protection-system | reactor trip breaker A position |
| «TRIP-BKR-B» | rps.trip_breaker.b.position |
enum[OPEN,CLOSED] | reactor-protection-system | reactor trip breaker B position |
Notes¶
- This page is generated. Edit by changing the sim-path declaration in the relevant procedure's tag appendix and rebuilding via
bun scripts/build-sim-bindings.ts. - Tags appearing in scenarios but not yet in any procedure are out of scope (see OD-18 in PLAN §25).
- Future bindings for other simulators (BNL Generic PWR, IAEA basic PWR) live in sibling pages
bnl.md,iaea.mdetc.